Induct Wire Wound Fixed Resistor

RH1000K50R00H

RH1000K50R00H
(NSN) National Stock Number
5905-00-517-7169
Federal Supply Classification
5905 Resistor
Item Name Code
37403
Schedule B Code
8533390080
Summary

-50.0 to 50.0 temp coefficient of resistance in ppm per deg celsius, 49.900 ohms electrical resistance, -1.000 to 1.000 resistance tolerance in percent, 275.0 ambient temp in deg celsius at zero percent rated power, -55.0 to 275.0 temp range of temp coefficient in deg celsius, established reliability indicator

DAC HCC DMIL RNCC
E - - E
RNVC SADC MSDS RNAAC
8 - - TX
Identification

A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Exclut s suppressor, ignition interference. See also resistor (1), fixed, wire wound, noninductive.

INC FIIG Concept Condition
37403 A001A0 1 1
Specifications
Temp Coefficient Of Resistance In Ppm Per Deg Celsius
-50.0 to 50.0
Details A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.
Electrical Resistance
49.900 ohms
Details A measure of the opposition to the flow of electrical current.
Resistance Tolerance In Percent
-1.000 to 1.000
Details The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.
Ambient Temp In Deg Celsius At Zero Percent Rated Power
275.0
Details The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.
Temp Range Of Temp Coefficient In Deg Celsius
-55.0 to 275.0
Details The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.
Reliability Indicator
established
Details An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.
Reliability Failure Rate Level In Percent
0.010
Details The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.
Terminal Length
0.250 inches minimum and 0.374 inches maximum
Details A measurement of the longest dimension of a terminal,in distinction from width.
Body Length
0.688 inches minimum and 0.812 inches maximum
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
0.376 inches minimum and 0.500 inches maximum
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Body Height
0.375 inches minimum and 0.437 inches maximum
Details A measurement from the bottom to the top of the body,in distinction from depth.
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.552 inches minimum and 0.572 inches maximum
Details The distance between centerlines of mounting facilities parallel to the length of the item.
Power Dissipation Rating In Watts
6.000 free air
Details The maximum amount of electrical energy that can be expended by an item,expressed in watts.
Ambient Temp At Full Rated Power
25.0 deg celsius
Details The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.
Terminal Width
0.140 inches minimum
Details A measurement taken at right angles to the length of the terminal,in distinction from thickness.
Inclosure Type
encased
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Mounting Hole Size
0.089 inches minimum and 0.099 inches maximum
Details Designates the size of the relative or proportionate dimension of the mounting hole.
Terminal Type
tab, solder lug
Details Indicates the type of terminal for providing electrical connection to the item.
Style Designator
axial terminal (s)
Details The style designation indicating the configuration that most nearly corresponds to the appearance of the item.
Test Data Document
81349-mil-r-39009 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).
Details The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
Specification/Standard Data
81349-mil-39009/1 government specification
Details The document designator of the specification or standard which established the item of supply.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
5905005177169 A00AM 9 - 6 9 - YP
0811-1003 28480 5 - C 1 - TX
0811-2650 28480 5 - E 8 - TX
S10-41 48294 4 - C 1 - 48
0811-2650 1LQK8 5 - E 8 - ZZ
RH-10-50 0HMS 1% 91637 3 - C 1 - ZZ
RH10000D50R00F 91637 3 - E 8 - ZZ
RH19-50-0HM-1 91637 1 - C 1 - ZZ
337676-1 56232 1 - E 8 - ZZ
MIL-PRF-39009/1 81349 E - 4 1 - ZZ
MIL-R-39009/1 81349 E - 5 9 - TX
RER65F49R9 81349 3 - E 8 - KE
RER65F49R9R 81349 E - 2 2 - TX
RER65F50R0P 81349 E - E 8 - ZZ
RER65G49R9R 81349 6 - C 1 - ZZ
RH-10-50 0HMS 3 91673 3 - C 1 - ZZ
RH-10-50 0HMS 3% 91673 3 - C 1 - ZZ
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N A A -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
35140 - P -
RVC WCC TCC SHC
- 72D Z 9
Price and Availability Quote

Send us a quick request for quote using the form below:

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Fast Quote Times
  • Qualified sales team
  • 100% Product Inspections
  • Counterfeit Parts Prevention
Manufacturer
VISHAY DALE ELECTRONICS, LLC DIV VISHAY AMERICAS
CAGE: 91637
COLUMBUS , NE , 68601-3647
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5905-00-517-7169
What is the NIIN of the NSN 5905-00-517-7169?
The National Item Identification Number (NIIN) of the NSN 5905-00-517-7169 is 00-517-7169
When the NSN 5905-00-517-7169 was assigned to the Federal Catalog?
It was assigned 50 years ago, on Sun, Aug 11, 1974
Does the NSN 5905-00-517-7169 contain any precious metals?
Does not contain precious metal
Does the NSN 5905-00-517-7169 contain any hazardous material?
No data in HMIRS
What is the ESD classification of NSN 5905-00-517-7169?
No known electrostatic discharge

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

We are one of the largest suppliers of National Stock Number (NSN) parts in the world. Here at NSN Equipment, we live on the cutting edge to give you the best service we possibly can.

And that service is why our customers return to us time and time again. Our credibility and our accolades only serve as testament to our industry-leading nature.

Contact
3555 Agricultural Center Dr.
St. Augustine, FL, 32092
United States
© 2025 NSN Equipment, Inc. All rights reserved.
Made in USA